품질 AC2541 트랜스듀서용 어쿠스틱 렌즈 공장

AC2541 트랜스듀서용 어쿠스틱 렌즈

Acoustic Lens For AC2541 Transducer ► Brief Description The lens works in tandem with the electronic focusing of the convex array to ensure a high-quality image. While the electronic steering focuses the beam in the elevation (depth) and azimuthal (left-right) directions, the physical lens provides ...

품질 올림푸스 BF-P290 EVIS LUCERA ELITE 비디오 기관지용 가이드 렌즈 공장

올림푸스 BF-P290 EVIS LUCERA ELITE 비디오 기관지용 가이드 렌즈

Light Guide Lens For Olympus BF-P290 EVIS LUCERA ELITE Video Bronchoscope ► Brief Description The Olympus BF-P290 is an advanced video bronchoscope designed to enhance diagnostic and therapeutic procedures in the respiratory system. ► Features High-Quality Imaging Narrow Band Imaging (NBI) Ultra...

품질 스토르즈 울프 로드 렌즈 딱딱한 엔도스코프 부품 재고 판매 공장

스토르즈 울프 로드 렌즈 딱딱한 엔도스코프 부품 재고 판매

Detail Rod Lens: Brand Size(4mm) Storz 2.76*29 Stryker 2.68*21 Olympus 2.76*21.4 Wolf 2.76*274MM, 10MM all provided. Spare parts for Rigid Endoscope: Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover, Outer tube & Inner tube,Fiber,etc. More information just feel free to contact us. Guangzhou Care ...

품질 카를 스토르츠 27005BA 내시경 수리 공장

카를 스토르츠 27005BA 내시경 수리

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

품질 Olympus GIF-H170 위장경 수리용 공장

Olympus GIF-H170 위장경 수리용

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube ...

품질 Olympus A70940A 수리용 오토클레이브 가능 관절경 공장

Olympus A70940A 수리용 오토클레이브 가능 관절경

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

품질 Karl Storz 27005BA Cystoscope for repair 공장

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

품질 고쳐야 할 올림푸스 CF-240L 콜로노스코프 공장

고쳐야 할 올림푸스 CF-240L 콜로노스코프

Olympus CF-240L Colonoscope for repair ► Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens, C cover. Adjust the angle. ►Problem & Solutoin Brand Olympus Model CF-240L Fault Leakage...

품질 Stryker 30º 0502-503-030 laproscope for repair 공장

Stryker 30º 0502-503-030 laproscope for repair

Stryker 30º 0502-503-030 laproscope for repair ► Brief Description Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. ►Problem & Solutoin Brand ...