Found 90 products for "

flexible endoscope medical device repair training

"
품질 MAJ-210 OLYMPUS 유연한 엔도스코프용 바이오피스 밸브 공장

MAJ-210 OLYMPUS 유연한 엔도스코프용 바이오피스 밸브

MAJ-210 OLYMPUS BIOPSY VALVE FOR FLEXIBLE ENDOSCOPE ► Brief Description The Olympus MAJ-210 is a single-use, sterile biopsy valve designed for use with a range of Olympus endoscopes. It's a critical accessory for various endoscopic procedures. ► Features Instrument Access: Its primary function is to provide a sealed entry point for inserting and exchanging endoscopic instruments (such as biopsy forceps, snares, cytology brushes, or other therapeutic tools) through the

품질 플렉서블 엔도스코프용 올림푸스 Bw-20t 청소 브러쉬 공장

플렉서블 엔도스코프용 올림푸스 Bw-20t 청소 브러쉬

Olympus Bw-20t Cleaning Brush ► Brief Description The Olympus BW-20T is a widely used and essential reusable cleaning brush specifically designed for the manual cleaning of the instrument channels of Olympus flexible endoscopes. This brush plays a crucial role in the reprocessing of endoscopes to ensure patient safety and effective device function. ► Features Mechanical Cleaning of Instrument Channels: The primary function of the BW-20T is to mechanically scrub and remove

품질 플렉서블 엔도스코프 부품 CCD 드라이버 보드 PENTAX EC-3890LK 콜로노스코프 공장

플렉서블 엔도스코프 부품 CCD 드라이버 보드 PENTAX EC-3890LK 콜로노스코프

CCD Driver Board For PENTAX EC-3890LK Colonoscope ► Brief Description The CCD Driver Board for the PENTAX EC-3890LK is a critical internal electronic component located within the video colonoscope. Its primary role is to drive the Charge-Coupled Device (CCD) image sensor located at the distal tip of the endoscope. It manages the precise timing signals required to capture high-resolution medical images and prepares the raw video data for transmission back to the main PENTAX

품질 유연한 엔도스코프 부품 펜택스 EG-27i10 가스트로스코프 PCB 보드 CCD 드라이브 보드 공장

유연한 엔도스코프 부품 펜택스 EG-27i10 가스트로스코프 PCB 보드 CCD 드라이브 보드

Bending Rubber For Olympus CF-H290I Colonoscope ► Brief Description The CCD Driver Board for PENTAX EG-27i10 is a critical, high-precision electronic subassembly located within the connector or control body of the PENTAX i10-series video gastroscope. Acting as the primary hardware interface between the endoscope’s distal end Megapixel CCD (Charge-Coupled Device) sensor and the external video processor (such as the PENTAX EPK-i series), this board manages low-level timing,

품질 Olympus ENF-GP 섬유 비인두 후두경 수리용 공장

Olympus ENF-GP 섬유 비인두 후두경 수리용

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber ►Problem & Solutoin Brand Olympus Model ENF-GP Fault 1. Image with black point and image bundle broken 2. Light

품질 수리용 OLYMPUS TJF-Q180V 전자 십이지장경 공장

수리용 OLYMPUS TJF-Q180V 전자 십이지장경

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix tube are worn; 6. The forceps elevator handle is damaged; 7. The handle shell is severely cracked. Solution: Replacement: Insertion tube, handle shell, light guide tube, snake

품질 1898200T M4 스트레이트샷 마이크로디브라이더 및 핸드피스 수리용 공장

1898200T M4 스트레이트샷 마이크로디브라이더 및 핸드피스 수리용

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside

품질 정비용 GE RIC6-12-D 내구성 탐사선 공장

정비용 GE RIC6-12-D 내구성 탐사선

GE RIC6-12-D endocavity probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. ►Problem & Solutoin Brand GE Model RIC6-12-D Fault Lens problem Solution Replace lens,Clean cable ► Common issues with RIC6-12-D Probe Dome Damage and Fluid Leaks Image Dropouts (Dead Elements) Cable and Connector Issues Motor/Steering Failure (for 4D functionality) If your instrument has any of the above problems or others, please feel free to contact us for

품질 정비용 OLYMPUS TJF-Q180V DUODENOSCOPE 공장

정비용 OLYMPUS TJF-Q180V DUODENOSCOPE

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR ► Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. Solution: Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD). ►Problem & Solutoin Brand OLYMPUS Model TJF-Q180V Fault 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5.