품질 수리용 올림푸스 CHF-P20Q 내시경 공장

수리용 올림푸스 CHF-P20Q 내시경

Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & ...

품질 정비용 올림푸스 CF-H190L 콜로노스코프 공장

정비용 올림푸스 CF-H190L 콜로노스코프

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

품질 Olympus GIF-Q180 위내시경 수리용 공장

Olympus GIF-Q180 위내시경 수리용

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

품질 정비용으로 Olympus의 GIF-XQ240 위장경 공장

정비용으로 Olympus의 GIF-XQ240 위장경

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common ...

품질 수리용 OLYMPUS TJF-Q180V 전자 십이지장경 공장

수리용 OLYMPUS TJF-Q180V 전자 십이지장경

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...

품질 T-A0015 카를 스토르츠 이미지 1 TH110 HX 22201020 카메라 헤드 공장

T-A0015 카를 스토르츠 이미지 1 TH110 HX 22201020 카메라 헤드

T-A0015 Repair tool for Karl Storz Image 1 TH110 HX 22201020 Camera Head Product Description 1. Introduction T-A0015 Repair tool for Karl Storz Image 1 TH110 HX 22201020 Camera Head Brand-new Perfectly repair camera head without scratch 2. Characteristics and Advantages Number:T-A0015 Features: ...

품질 T-A0011 STORZ 이미지 1 H3 HD 22220150 카메라 헤드 수리 도구 공장

T-A0011 STORZ 이미지 1 H3 HD 22220150 카메라 헤드 수리 도구

T-A0011 Repair tool for STORZ Image 1 H3 HD 22220150 Camera Head Product Description 1. Introduction T-A0011 Repair tool for STORZ Image 1 H3 HD 22220150 Camera Head Brand-new Perfectly repair STORZ H3 Camera Head 2. Characteristics and Advantages Number:T-A0011 Features: Durable, Portable, Multi...

품질 Aloka UST-5413 선형 어레이 초음파 프로브 수리 공장

Aloka UST-5413 선형 어레이 초음파 프로브 수리

Aloka UST-5413 linear array ultrasound probe for repair ► Brief Description Fault: Lens break. Solution: Replace lens. ►Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens ► Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConne...

품질 고쳐야 할 올림푸스 CF-240L 콜로노스코프 공장

고쳐야 할 올림푸스 CF-240L 콜로노스코프

Olympus CF-240L Colonoscope for repair ► Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens, C cover. Adjust the angle. ►Problem & Solutoin Brand Olympus Model CF-240L Fault Leakage...