dynamical system cable
"
수리를 위한 C5-1 볼록 프로브
C5-1 convex probe for repair ► Brief Description Fault:Lens problem, cable broken, without strain relief. Solution:Replace probe lens, replace a new cable, replace strain relief. ►Problem & Solutoin Model C5-1 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, replace a new cable, replace strain relief ► Common issues with C5-1 probe Cable and Connector Damage Acoustic Lens Damage Crystal/Element Failure Intermittent Signal Loss or Noise
STORZ 카메라 헤드 H3-ZA 수리
STORZ Camera Head H3-ZA For Repair ► Brief Description Fault:Image streaks frequently,cable loose contact and aged. Solution: Replace cable kit. ►Problem & Solutoin Brand STORZ Model H3-ZA Fault Image streaks frequently,cable loose contact and aged Solution Replace cable kit ► Common issues with H3-ZA Camera Image Quality Problems Connection and Communication Issues Functional Abnormalities Physical Damage If your instrument has any of the above problems or others, please
Olympus MAJ-1430 비디오 피그테일 CV-180 및 CV-190 비디오 프로세서
Olympus MAJ-1430 Video Pigtail for CV-180 and CV-190 video processors ► Brief Description The Olympus MAJ-1430 Video Pigtail is a vital connection cable in Olympus endoscopy systems. It's designed to facilitate the transmission of video signals from a flexible endoscope to a video processor, enabling real-time visualization of endoscopic procedures on a monitor. ► Features It physically and electronically connects the video endoscope (which captures images from within the
정비용 GE RIC6-12-D 내구성 탐사선
GE RIC6-12-D endocavity probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. ►Problem & Solutoin Brand GE Model RIC6-12-D Fault Lens problem Solution Replace lens,Clean cable ► Common issues with RIC6-12-D Probe Dome Damage and Fluid Leaks Image Dropouts (Dead Elements) Cable and Connector Issues Motor/Steering Failure (for 4D functionality) If your instrument has any of the above problems or others, please feel free to contact us for
1898200T M4 스트레이트샷 마이크로디브라이더 및 핸드피스 수리용
1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside
Cf-H290i 올림푸스 콜로노스코프 Ccd 객체 렌즈 유연한 엔도스코프의 부품
Detail CCD Objective lens for Olympus CF-H290I Colonoscope Spare parts for Olympus GIF-HQ290,GIF-H290,GIF-100,GIF-130,GIF-140,GIF-160 ,GIF-H260,GIF-Q160,GIF-Q180,GIF-Q260 ,GIF-Q30,GIF-V,GIF-V2,GIF-V70,GIF-XQ140,GIF-XQ20,GIF-XQ230,GIF-XQ240,GIF-XQ260,GIF-XP260,GIF-Q260//CF-HQ290I,CF-140,CF-140I,CF-200L,CF-240I,CF-40I,CF-H260AI,CF-H260AZI,CF-LB3W,CF-Q160I,CF-Q240I ,CF-Q240L,CF-Q260AI,CF-V70I,CF-V70,CF-VI//JF-240,TJF-140R,TJF-200//BF-1T180 ,BF-1T240,BF-1T260,BF-160,BF-240,BF
Olympus GIF-HQ290 가스트로스코프 부품의 원본 디스탈 헤드
Distal Head for Olympus GIF-HQ290 Gastroscope Parts Spare parts for flexible endoscope: insert tube, light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc. Spare parts for Ultrasound system: power supply, probe(Lens, strain relief, housing, cable, crystal), monitor, mainboard, TR board, etc. Spare parts for rigid endoscope: rod lens, gap ring, outer tube, inner tube, objective lens, prism,light bundle,
원본 디스탈 헤드: 올림푸스 CF-HQ290I 콜로노스코프 부품
Distal Head for Olympus CF-HQ290I Gastroscope Parts Spare parts for flexible endoscope: insert tube, light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc. Spare parts for Ultrasound system: power supply, probe(Lens, strain relief, housing, cable, crystal), monitor, mainboard, TR board, etc. Spare parts for rigid endoscope: rod lens, gap ring, outer tube, inner tube, objective lens, prism,light bundle,
EPlQ/X5-1 탐사 2차원 이미지 수리용 비정상
EPlQ/X5-1 Probe For Repair ► Brief Description Fault: 2D image abnormal Solution: Replace scanhead ►Problem & Solutoin Model EPlQ/X5-1 Fault 2D image abnormal Solution Replace scanhead ► Common Problems & Symptoms Image Artifacts (black lines, dropouts, flickering) → Damaged elements or cable No Image/Dead Probe → Cable break, connector issues, or internal failure Lens Damage (cracks, delamination) → Acoustic coupling issues Error Messages ("Probe Not Recognized") → Faulty